  Isolation Transformer Style7 Receptacle  
    17.0   17.1            
   

Related Standards

  • FAA AC 150/5345-47 L-831
  • ICAO Aerodrome Design Manual, Part 5, Para. 3.2.1.7
  • IEC TS 61823
  • STANAG 3316


   
                     
   
APPLICATIONS
  • In supplying the airfield lighting from a series circuit.
   
                     
   
IMPORTANT FEATURES
  • IEC 61823 certified
  • The primary windings of all transformers are connected to a constant current regulator and the secondaries are connected to runway or taxiway lights. Thus the primary and secondary windings being separated, safety of the personnel is acquired.
  • Operates without time limit in short circuit, open circuit and full load conditions.
  • The plugs and receptacles enable easy connection
  • Transformers can operate continuously at 10% over load
  • The Toroidal core made of low loss grain oriented laminations. Primary and secondary windings are made of double enamelled copper wire
  • Two single core primary leads; 0.60m, 1x6mm2, 5 kV with factory moulded Style 2 plug and Style 9 receptcle
  • One two core secondary lead; 1.20m, 2×2.5mm2, 1 kV with factory moulded Style 7 or Style 8 receptacle
  • Transformers are designed for continuous operation
  • Transformers are resistant to salty water, fuel, oil and ozone in ambient temperatures between -55°C and +65°C Can directly be buried in soil